ISSN 2756-3391
African Journal of Parasitology Research | Vol. 14, No. 11, November 2026 | pp. 991–997
DOI: 10.46882/AJPR/140991
Article Type: Research Article
Title: Diagnostic accuracy of circulating cathodic antigen urine cassettes versus Kato-Katz thick smears for Schistosoma mansoni surveillance in low-endemicity settings
Names of Authors: Hannah Lindholm¹*, Josephat Nkurunziza², Wei-Jie Tan³
Authors’ Affiliations: ¹Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, Stockholm, Sweden. ²Department of Biomedical Laboratory Sciences, University of Rwanda, Kigali, Rwanda. ³Department of Microbiology and Immunology, National University of Singapore, Singapore, Singapore.
Abstract: Accurate diagnostic tools are crucial for verifying schistosomiasis interruption in regions undergoing repeated mass drug administration campaigns. In this study, we aimed to compare the diagnostic performance of point-of-care circulating cathodic antigen (POC-CCA) urine assays against duplicate Kato-Katz stool smears in low-intensity Schistosoma mansoni settings. Matched stool and urine samples were collected from 540 adults and children across 9 sentinel communities, with a subset of 200 samples analyzed by real-time quantitative PCR (qPCR) as a composite reference standard. Kato-Katz microscopy identified S. mansoni eggs in 9.6 percent (52/540) of participants, with 88.5 percent of positive cases classified as light-intensity infections (<100 eggs per gram). Conversely, POC-CCA yielded a positivity rate of 28.1 percent (152/540) when trace results were considered positive, and 21.3 percent when trace results were scored as negative. Against qPCR, POC-CCA demonstrated a sensitivity of 89.4 percent and specificity of 86.2 percent, substantially outperforming Kato-Katz sensitivity (36.8 percent). Conventional fecal microscopy severely underestimates true infection prevalence following preventive chemotherapy. Incorporating POC-CCA testing into routine surveillance protocols will improve the detection of light infections and guide targeted treatment decisions.
Keywords: Schistosoma mansoni, POC-CCA, Kato-Katz, Diagnostic sensitivity, Low endemicity
Citation: Lindholm H, Nkurunziza J, Tan WJ (2026). Diagnostic accuracy of circulating cathodic antigen urine cassettes versus Kato-Katz thick smears for Schistosoma mansoni surveillance in low-endemicity settings. African Journal of Parasitology Research, 14(11): 991–997. DOI: 10.46882/AJPR/140991
Manuscript Timeline: Received: June 20, 2026; Revised: August 02, 2026; Accepted: September 03, 2026; Published: November 21, 2026