ISSN 2756-3391
African Journal of Parasitology Research | Vol. 14, No. 9, September 2026 | pp. 822–828
DOI: 10.46882/AJPR/140822
Article Type: Research Article
Title: Comparative efficacy of loop-mediated isothermal amplification and Kato-Katz microscopy for diagnosing Schistosoma mansoni in low-endemicity settings
Names of Authors: David Mwangi Njoroge¹*, Hannah Claire Miller², Rajesh Kumar Sharma³
Authors’ Affiliations: ¹Centre for Biotechnology Research and Development, Kenya Medical Research Institute, Nairobi, Kenya. ²Department of Tropical Disease Biology, Liverpool School of Tropical Medicine, Liverpool, United Kingdom. ³Department of Parasitology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Abstract: Schistosoma mansoni causes intestinal schistosomiasis, and accurate diagnosis in low-transmission areas is critical for verifying disease elimination. In this study, we compared the diagnostic performance of a loop-mediated isothermal amplification (LAMP) assay against duplicate Kato-Katz thick smears among school-aged children in a low-endemicity district. A total of 450 stool samples were collected from children aged 6 to 14 years and analyzed using both duplicate Kato-Katz slides and a closed-tube colorimetric LAMP assay targeting the Sm1-7 repetitive sequence. Duplicate Kato-Katz microscopy identified S. mansoni eggs in 38 children (8.4 percent), with the majority (84.2 percent) classified as light-intensity infections (<100 eggs per gram of feces). In contrast, the Sm1-7 LAMP assay detected S. mansoni DNA in 97 children (21.6 percent), capturing all 38 microscopy-positive cases plus 59 additional sub-microscopic infections. Using a composite reference standard, LAMP demonstrated a sensitivity of 98.9 percent and specificity of 96.4 percent, whereas Kato-Katz sensitivity dropped to 39.2 percent. The LAMP reaction was completed within 45 minutes at 63 degrees Celsius without requiring sophisticated thermal cyclers. Conventional Kato-Katz microscopy substantially underestimates S. mansoni prevalence in low-intensity settings. Colorimetric LAMP offers a rapid, sensitive, and field-deployable alternative for schistosomiasis surveillance and post-treatment monitoring.
Keywords: Schistosoma mansoni, Loop-mediated isothermal amplification, Kato-Katz, Low-endemicity diagnostics, Schistosomiasis
Citation: Njoroge DM, Miller HC, Sharma RK (2026). Comparative efficacy of loop-mediated isothermal amplification and Kato-Katz microscopy for diagnosing Schistosoma mansoni in low-endemicity settings. African Journal of Parasitology Research, 14(9): 822–828. DOI: 10.46882/AJPR/140822
Manuscript Timeline: Received: February 24, 2026; Revised: April 10, 2026; Accepted: May 16, 2026; Published: September 14, 2026